[1] SCHREURS B,HANNINK G. Total joint arthroplasty in younger patients:Heading for trouble?[J]. The Lancet,2017,389(10077):1374-1375. [2] LEARMONTH I D,YOUNG C,RORABECK C. The operation of the century:Total hip replacement[J]. The Lancet,2007,370(9597):1508-1519. [3] DALTON J,COOK S,THOMAS K,et al. The Effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants[J]. JBJS,1995,77(1):97-110. [4] JASTY M,BRAGDON C,BURKE D,et al. In vivo skeletal responses to porous-surfaced implants subjected to small induced motions[J]. JBJS,1997,79(5):707-714. [5] SØBALLE K,HANSEN E,RASMUSSEN H,et al. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions[J]. Journal of Orthopaedic Research,1992,10(2):285-299. [6] FEHRING K,OWEN J,KURDIN A,et al. Initial stability of press-fit acetabular components under rotational forces[J]. The Journal of Arthroplasty,2014,29:1038-1042. [7] CHEN Z,WANG C,JIANG W,et al. A review on surgical instruments of knee arthroscopic debridement and total hip arthroplasty[J]. Procedia CIRP,2017,65:291-298. [8] 陈志桦,王成勇,汤娜,等. 髋关节置换术中关键手术刀具的研究[J]. 工具技术,2017,51(3):8-14.CHEN Zhiye,WANG Chengyong,TANG Na,et al.Research on surgical instrument of total hip arthroplasty[J]. Tool Engineering,2017,51(3):8-14. [9] KIM Y,BROWN T,PEDERSEN D,et al. Reamed surface topography and component seating in press-fit cementless acetabular fixation[J]. The Journal of Arthroplasty,1995,10:S14-S21. [10] MACDONALD W,CARLSSON L,CHARNLEY G,et al. Inaccuracy of acetabular reaming under surgical conditions[J]. The Journal of Arthroplasty,1999,14(6):730-737. [11] LEVASSEUR A,MENARD J,SONGMENE V,et al. Quality of reamed surface using serrated blades as compared to a conventional acetabular reamer[C]//Proceedings of the ASME 2013 International Mechanical Engineering Congress and Exposition,2013V11T-V16T. [12] 江文涛. 髋关节置换术中髋臼锉的切削机理及刀具优化[D]. 广州:广东工业大学,2018. JIANG Wentao. Machining mechanism and optimization of reamer in hip replacement[D]. Guangzhou:Guangdong University of Technology,2018. [13] BAAD-HANSEN T,KOLD S,FLEDELIUS W,et al. Comparison of performance of conventional and minimally invasive surgery acetabular reamers[J]. Clinical Orthopaedics and Related Research,2006,448:173-179. [14] DAVIDSON D,WILSON D C,JANDO V T,ET al. Accuracy of cut-off acetabular reamers for minimally invasive THA[J]. Clinical Orthopaedics and Related Research,2006,453:168-172. [15] SLOTKIN S,FRISCH N B,ROC G,et al. Hemispherical and minimally invasive total hip reamers:A biomechanical analysis of use and design[J]. Arthroplasty Today,2017,3(2):131-136. |