• CN:11-2187/TH
  • ISSN:0577-6686

›› 2012, Vol. 48 ›› Issue (21): 84-90.

• 论文 • 上一篇    下一篇

扫码分享

基于电动机电流信号双谱分析的齿轮传动故障诊断

陈峙;王铁;谷丰收;MANSAF Haram;ANDREW Ball   

  1. 太原理工大学机械工程学院;哈德斯菲尔德大学计算与工程学院
  • 发布日期:2012-11-05

Gear Transmission Fault Diagnosis Based on the Bispectrum Analysis of Induction Motor Current Signatures

CHEN Zhi; WANG Tie;GU Fengshou;MANSAF Haram;ANDREW Ball   

  1. School of Mechanical Engineering, Taiyuan University of Technology School of Computing and Engineering, University of Huddersfield
  • Published:2012-11-05

摘要: 电动机电流信号分析广泛应用于电动机本身的监测,但用该项技术监测与电动机相连设备的研究却很少。提出应用异步电动机的电流信号的调制信号双谱分析方法,实现对与电动机连接的齿轮传动系统的故障监测。试验表明调制信号双谱波峰的升高可以作为检测故障的依据。齿轮的故障可通过观测相关轴的双频波峰的变化进行诊断,与齿轮直接相连的轴产生较大的波峰增高,而与齿轮相邻的轴产生较小的波峰增高但轴不对中的故障可以只观测与该轴相应的双频波峰增高来确定。

关键词: 齿轮传动, 调制信号双谱, 故障监测, 异步电动机电流信号

Abstract: Motor current signal analysis has been an effective way for many years to monitor electrical machines. However, little research work has been reported in using this technique for monitoring their downstream equipment. The research investigating the characteristics of electrical current signals measured from an induction motor for monitoring faults from a downstream gear transmission system by a novel modulation signal (MS) bispectrum method. Both analytic analysis and experimental study are conducted based on a motor drive system and have found that the increase of bispectral peaks can be the basis of mechanical fault diagnosis. Particularly, a fault on a gear will causes a larger increase of the bispectral peak at both the gear shaft frequency and accompany with a smaller increase in the relating shaft frequency. However, a shaft misalignment only leads to a bispectrum peak increase at the shaft bifrequency along.

Key words: Fault diagnosis, Gear transmission, Modulated signal biopspectrum, Motor current signature

中图分类号: