• CN:11-2187/TH
  • ISSN:0577-6686

机械工程学报 ›› 2026, Vol. 62 ›› Issue (17): 236-245.doi: 10.3901/JME.260512

• 特邀专栏:人形机器人与具身智能 • 上一篇    

扫码分享

机器人关节电机的功率硬件在环模拟技术研究

刘钰鹏1, 马润林1, 邓家敏1, 陶永2, 徐东1   

  1. 1. 北京航空航天大学自动化科学与电气工程学院 北京 100191;
    2. 北京航空航天大学机械工程及自动化学院 北京 100191
  • 收稿日期:2025-11-13 修回日期:2026-04-19 发布日期:2026-11-20
  • 作者简介:刘钰鹏,男,1991年出生,博士,助理教授,硕士研究生导师。主要研究方向为硬件在环控制技术、电机控制。E-mail:yupengliu@buaa.edu.cn;徐东(通信作者),男,1979年出生,博士,副教授,硕士研究生导师。主要研究方向为电机控制,机械臂控制及振动抑制技术。E-mail:xd@buaa.edu.cn

Research on Power Hardware-in-the-loop Emulation Technology for Joint Motors of Robots

LIU Yupeng1, MA Runlin1, DENG Jiamin1, TAO Yong2, XU Dong1   

  1. 1. School of Automation Science and Electrical Engineering, Beihang University, Beijing 100191;
    2. School of Mechanical Engineering and Automation, Beihang University, Beijing 100191
  • Received:2025-11-13 Revised:2026-04-19 Published:2026-11-20

摘要: 在工业机器人、人形机器人等各种形态、功能的操作设备中,关节电机的精准度、动态响应速度与稳定性直接决定该类设备动作复现精度及肢体灵活性。鉴于实物测试周期长、成本高,功率硬件在环模拟(Power hardware-in-the-loop, PHIL)已成为电机驱动系统研发与验证的核心技术,替代实际电机实现复杂工况下的模拟加载与特性复现。然而,现有PHIL模拟器的端口电流控制普遍存在响应迟滞、精度不足的问题,严重制约了测试结果的置信度。针对该问题,提出了一种应用于功率硬件在环模拟系统的滑模电流控制(Sliding mode current control, SMCC)策略,并与传统比例-积分(Proportional-integral, PI)控制及模型预测控制(Model predictive control, MPC)开展性能对比。研究结果表明,所提滑模电流控制策略在电流跟踪速度与控制精度上均具有显著优势,可为关节电机驱动的高效测试提供技术支撑。

关键词: 机器人, 关节电机, 功率硬件在环模拟, 滑模电流控制

Abstract: In various types and functions of operating equipment such as industrial robots and humanoid robots, the accuracy, dynamic response speed, and stability of joint motors directly determine the motion reproduction precision and limb flexibility of such equipment. Given the high cost and prolonged cycles associated with physical testing, Power Hardware-in-the-Loop (PHIL) emulation has emerged as a key technology for the development and validation of motor drive systems. It serves as a substitute for actual motors, enabling load emulation and characteristic replication under complex operating conditions. However, existing PHIL emulators frequently suffer from response latency and insufficient precision in current control, which severely compromises the fidelity of test results. Regarding this issue, a sliding mode current control (SMCC) strategy is proposed for PHIL systems and performance is compared with traditional proportional-integral (PI) control and model predictive control (MPC). Experimental results demonstrate that the proposed SMCC strategy exhibits significant superiority in both current tracking speed and control precision, providing technical support for the efficient testing of joint motor drives.

Key words: robot, joint motor, power hardware-in-the-loop, sliding mode current control

中图分类号: