• CN:11-2187/TH
  • ISSN:0577-6686

机械工程学报 ›› 2026, Vol. 62 ›› Issue (18): 438-444.doi: 10.3901/JME.260665

• 交叉与前沿 • 上一篇    

扫码分享

管道轴向裂纹全聚焦成像与定量检测

金士杰, 苏嘉凯, 李潇, 史思琪, 狄成军, 罗忠兵   

  1. 大连理工大学材料科学与工程学院 大连 116024
  • 收稿日期:2025-12-15 修回日期:2026-05-13 发布日期:2026-11-20
  • 作者简介:金士杰,男,1984年出生,博士,副教授,博士研究生导师。主要研究方向为材料检测与无损评价。E-mail:jinshijie@dlut.edu.cn;罗忠兵(通信作者),男,1984年出生,博士,教授,博士研究生导师。主要研究方向为材料检测与无损评价。E-mail:zhbluo@dlut.edu.cn
  • 基金资助:
    国家自然科学基金资助项目(52275520,51905079)。

TFM Imaging and Quantitative Detection of Axial Cracks in Pipelines

JIN Shijie, SU Jiakai, LI Xiao, SHI Siqi, DI Chengjun, LUO Zhongbing   

  1. School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024
  • Received:2025-12-15 Revised:2026-05-13 Published:2026-11-20

摘要: 超声全聚焦方法(Total focusing method, TFM)因具有高分辨力和理想的聚焦效果,已广泛应用于平板结构缺陷识别与定量。然而,在管道结构中实施轴向裂纹检测时,由于曲面几何特征的影响,超声波在传播过程中会发生明显的折射与发散,导致传统TFM成像结果出现位置偏移、形貌畸变以及尺寸定量误差增大等问题。结合TFM原理与管道曲率对超声束的发散作用,对延时叠加所用阵列信号声时进行修正,实现了轴向裂纹的成像表征与精准定量。仿真和试验结果显示,对于外径110 mm碳钢管道内部长度5 mm、中心深度12 mm、倾角30°和45°的轴向裂纹,未考虑管道曲率时的长度、角度和中心深度测量误差分别达到25.11%、27.35°、13.33%,而管道TFM成像后的定量误差分别不超过11.59%、6.75°与3.13%。最后,从理论上分析了TFM检测位置对缺陷深度定量误差的影响,进一步表明所提方法的有效性和必要性。

关键词: 超声检测, 全聚焦方法, 管道, 轴向裂纹, 定量检测

Abstract: The ultrasonic total focusing method (TFM), featuring high resolution and excellent focusing performance, has been widely used to identify and quantify defects in plates. However, obvious refraction and divergence of ultrasonic waves during propagation are caused by the curved geometry when axial cracks in pipelines are detected. As a result, the conventional TFM imaging results exhibit position deviation, shape distortion, and increased quantitative errors in defect sizing. The travel times of array signals used for the delay-and-sum beamforming are corrected to realize the imaging characterization and accurate quantification of axial cracks by combining TFM principle and the divergence effects of pipeline curvature on ultrasonic beams. The simulated and experimental results show that the measurement errors of crack lengths, angles and central depths without considering pipeline curvature are respectively up to 25.11%, 27.35° and 13.33% for the axial cracks with 5 mm length, 12 mm central depth and 30° and 45° inclined angles in carbon steel pipeline with an out wall diameter of 110 mm. In contrast, the quantitative errors in TFM images of pipelines are within 11.59%, 6.75° and 3.13%, respectively. Finally, the influences of TFM detection position on the measurement errors of defect depths are theoretically analyzed, further demonstrating the effectiveness and necessity of the proposed method.

Key words: ultrasonic detection, total focusing method, pipeline, axial cracks, quantitative detection

中图分类号: