[1] DRINKWATER B W, WILOX P D. Ultrasonic arrays for non-destructive evaluation:A review[J]. NDT & E International, 2006, 39:525-541. [2] GUEUDRE C, MARREC L, MOYSAN J, et al. Direct model optimisation for data inversion. application to ultrasonic characterisation of heteroge-neous welds[J]. NDT & E International, 2009, 42:47-55. [3] LUPIEN V, HASSAN W, DUMAS P. Improved titanium billet inspection sensitivity through optimized phased array design, Part I:Design technique, modeling and simulation[C]//AIP Conference, 2006, 820(1):853-860. [4] GUAN X, ZHANG J, RASSELKORDE E M, et al. Material damage diagnosis and characterization for turbine rotors using three-dimensional adaptive ultrasonic NDE data reconstruction techniques[J]. Ultrasonics, 2014, 54:516-525. [5] SMITH R A, BENDING J M, JONES L D, et al. Rapid ultrasonic inspection of ageing aircraft[J]. Insight, 2003, 45(3):174-177. [6] SONG S J, SHIN H J, JANG Y H. Development of an ultrasonic phased array system for non-destructive tests of nuclear power plant components[J]. Nuclear Engineering Design, 2002, 214:151-161. [7] LOZEV M G, SPENCER R L, HODGKINSON D. Optimized inspection of thin-walled pipe welds using advanced ultrasonic techniques[J]. J. Press. Vessel Technol. Trans. ASME, 2005, 127:237-243. [8] YANG P, CHEN B, SHI K R. A novel method to design sparse linear arrays for ultrasonic phased array[J]. Ultrasonics, 2006, 44:717-721. [9] CHATILLON S, CATTIAUX G, SERRE M, et al. Ultrasonic non-destructive testing of pieces of complex geometry with a flexible array transducer[J]. Ultrasonics, 2000, 38:131-134. [10] PUEL B, LESSELIER D, CHATILLON S, et al. Optimization of ultrasonic arrays design and setting using a differential evolution[J]. NDT&E International, 2011, 44:797-803. [11] MAHAUT S, ROY O, BERONI C, et al. Development of phased array techniques to improve characterization of defect located in a component of complex geometry[J]. Ultrasonics, 2002, 40:165-169. [12] HOLMES C, DRINKWATER B W, WILCOX P D. Post-processing of the full matrix of ultrasonic transmit-receive array data for nondestructive evaluation[J]. NDT & E International, 2005, 38(8):701-711. [13] ZHANG J, DRINKWATER B W, WILCOX P D. Comparison of ultrasonic array imaging algorithms for non-destructive evaluation[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2013, 60(8):1732-1745. [14] SCHMERR L W. Fundamentals of ultrasonic nondestructive evaluation:A modeling approach[M]. New York:Plenum Press, 1998. [15] WOOH S C, SHI Y. Optimum beam steering of linear phased arrays[J]. Wave Motion, 1999, 29:245-265. [16] WOOH S C, WANG J Y. A simulation study of the beam steering characteristics for linear phased arrays[J]. Journal of Nondestructive Evaluation, 1999, 18(2):39-57. [17] CLAY A C, WOOH S C, AZAR L, et al. Experimental study of phased array beam steering characteristics[J]. Journal of Nondestructive Evaluation, 1999, 18(2):59-71. [18] HOLMES C, DRINKWATER B W, WILCOX P D. The post-processing of ultrasonic array data using the total focusing method[J]. Ultrasonics, 2004, 46(11):677-680. [19] FAN C, CALEAP M, PAN M, et al. A comparison between ultrasonic array beamforming and super resolution imaging algorithms for non-destructive evaluation[J]. Ultrasonics, 2014, 54:1842-1850. [20] ZHANG J, DRINKWATER B W, WILCOX P D, et al. Defect detection using ultrasonic arrays:The multi-mode total focusing method[J]. NDT & E International, 2010, 43(2):123-133. [21] STUTCLIFFE M, WESTON M, DUTTON B, et al. Real-time full matrix capture with auto-focussing of known geometry through dual layered media[C/CD]//51st Annual Conference of The British Institute of Non-Destructive Testing, 2012. [22] WESTON M, MUDGE P, DAVIS C, et al. Time efficient auto-focusing algorithms for ultrasonic inspection of dual-layered media using full matrix capture[J]. NDT & E International, 2012, 47:43-50. [23] ZHANG J, DRINKWATER B W, WILCOX P D. Efficient computation of delay law for imaging structure with a complex surface[C]//Joint UFFC, EFTF and PFM Symposium, 2014:139-142. [24] ZHANG J, DRINKWATER B W, WILCOX P D. Efficient immersion imaging of components with nonplanar surfaces[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2014, 61(8):1284-1795. [25] 周正干, 彭地, 李洋, 等. 相控阵超声检测技术中的全聚焦成像算法及其校准研究[J]. 机械工程学报, 2015, 54(10):1-6. ZHOU Zhenggan, PENG Di, LI Yang, et al. Ultrasonic phased array inspection on the wedge using full matrix data[J]. Journal of Mechanical Engineering, 2015, 54(10):1-6. [26] LI C, PAIN D, WILCOX P D, et al. Imaging composite material using ultrasonic arrays[J]. NDT & E International, 2013, 53:8-17. [27] YAN D, SUTCLIFFE M, WRIGHT B, et al. Ultrasonic imaging of full matrix capture acquired data for carbon fibre-reinforced polymer[J]. Insight, 2013, 55(9):477-481. [28] HOLMES C, DRINKWATER B W, WILCOX P D. Advanced post-processing for scanned ultrasonic arrays:Application to defect detection an classification in non-destructive evaluation[J]. Ultrasonic, 2008, 48:636-642. [29] HOLMES C, DRINKWATER B W, WILCOX P D. Advanced post-processing for scanned ultrasonic arrays:Application to defect detection and classification in non-destructive evaluation[J]. Ultrasonics, 2008, 48:636-642. [30] ZHANG J, DRINKWATER B W, WILCOX P D. Defect characterization using an ultrasonic array to measure the scattering coefficient matrix[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2008, 55(10):2254-2265. [31] BAI L, VELICHKO A, DRINKWATER B W. Ultrasonic characterization of crack-like defects using scattering matrix similarity metrics[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2015, 62(3):545-559. [32] HUNTER A J, DRINKWATER B W, WILCOX P D. The wave number algorithm for full matrix imaging using an ultrasonic array[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2008, 55(11):2450-2462. [33] VELICHKO A, WILCOX P D. Reversible back-propagation imaging algorithm for post processing of ultrasonic array data[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2009, 56(11):2492-2503. [34] LABYED Y, HUANG L. Ultrasound time-reversal music imaging with diffraction and attenuation compensation[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2012, 59(10):2186-2200. [35] DAVY M, MINONZIO J G, de ROSNY J, et al. Influence of noise on subwavelength imaging of two close scatterers using time reversal method:Theory and experiments[J]. Prog. Electromagn. Res., 2009, 98:333-358. [36] ASGEDOM E G, GELIUS L J, AUSTENG A, et al. Time-reversal multiple signal classification in case of noise:A phase-coherent approach[J]. J. Acoust. Soc. Am., 2011, 130:2024-2034. [37] de ROSNY J, PRADA C. Comment on multiple scattering:the key to unravel the subwavelength world from the far-field pattern of a scattered wave[J]. Phys. Rev. E, 2007, 75(2):048601. [38] GRUBER F K, MARENGO E A, DEVANEY A J. Time-reversal imaging with multiple signal classification considering multiple scattering between the targets[J]. J. Acoust. Soc. Am., 2004, 115 (6):3042-3047. [39] FAN C, PAN M, LUO F, et al. Multi-frequency time-reversal-based imaging for ultrasonic nondestructive evaluation using full matrix capture[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2014, 61(12):2067-2074. [40] VELICHKO A, WILCOX P D. An analytical comparison of ultrasonic array imaging algorithms[J]. Acoustic Society of American, 2010, 127(4):2377-2384. [41] MOALLEMI N, SHAHBAZPANAHI S. A new model for array spatial signature for two-layer imaging with applications to nondestructive testing using ultrasonic arrays[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2015, 63(10):2264-2475. [42] DRINKWATER B W, BOWLER A I. Ultrasonic array inspection of the clifton suspension bridge chain-links[J]. Insight, 2009, 51(9):491-498. [43] LONG R, RUSSELL J, CAWLEY P. Ultrasonic phased array inspection using full matrix capture[C]//Insight, Non-Destructive Testing and Condition Monitoring, July 2012. 2012,54(7):380-385. [44] LANE C J L, DUNHILL T K, DRINKWATER B W. 3D ultrasonic inspection of anisotropic aerospace components[J]. Insight, 2013, 55(9):477-481. [45] NOWERS O D, DUXBURY D J, DRINKWATER B W. Accurate modelling of anisotropic effects in austenitic stainless steel welds[C/CD]//40th Annual Review of Progress in Quantitative Nondestructive Evaluation, 2013. [46] PAIN D, DRINKWATER B W. Detection of fibre waviness using ultrasonic array scattering data[J]. Journal of Nondestructive Evaluation, 2013, 32:215-227. [47] BULAVINOV A, DALICHOW M, KRÖNING M, et al. Quantitative ultrasonic testing of pressurized components using sampling phased array[C]//Proc. National Seminar on Non-Destructive Evaluation Dec, 2006:7-9. [48] BULAVINOV A, PINCHUK R, PUDOVIKOV S, et al. Industrial application of real-time 3D imaging by sampling phased array[C/CD]//European Conference for Nondestructive Testing, Moscow, 2010. [49] BERNUS L, BULAVINOV A, DALICHOW M, et al. Sampling phased array:A new technique for signal processing and ultrasonic imaging[J]. Insight, 2006, 48(9):545-549. [50] FELICE M V, VELICHKO A, WILCOX P D. Accurate Depth measurement of small surface-breaking cracks using an ultrasonic array post-processing technique[J]. NDT&E International, 2014, 68:105-112. [51] HUNTER A J, DRINKWATER B W, WILCOX P D. Least-squares estimation of imaging parameters for an ultrasonic array using known geometric image features[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2011, 58(2):414-426. [52] HUNTER A J, DRINKWATER B W, WILCOX P D. A model-based autofocus algorithm for ultrasonic imaging using a flexible array[J]. Review of Quantitative Nondestructive Evaluation, 2010, 29:863-870. [53] MCGILP A, DZIEWIERZ J, LARDNER T. Inspection of complex components using 2D arrays and TFM[C/CD]//53rd Annual Conference of the British Institute of Non-Destructive Testing, 2014. [54] ZHANG J, DRINKWATER B W, WILCOX P D. The use of ultrasonic arrays to characterize crack-like defects[J]. Journal of Nondestructive Evaluation, 2010, 29(4):222-232. [55] XU Na, ZHOU Zhenggan. Numerical simulation and experiment for inspection of corner-shaped components using ultrasonic phased array[J]. NDT&E International, 2014, 63:28-34. [56] MOALLEMI N, SHAHBAZPANAHI S. A distributed reflector localization approach to ultrasonic array imaging in non-destructive testing applications[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2014, 62(15):3863-3873. [57] QUAEGEBEUR N, MASSON P. Correlation-based imaging technique using ultrasonic transmit-receive array for non-destructive evaluation[J]. Ultrasonic, 2012, 52:1056-1064. [58] PORTZGEN N, GISOLF D, BLACQUIERE G. Inverse wave field extrapolation:A different NDI approach to imaging defects[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2007, 54(1):118-127. [59] MARTÍN-ARGUEDAS C J, ROMERO-LAORDEN D, MARTÍNEZ-GRAULLERA O, et al. An ultrasonic imaging system based on a new SAFT approach and a GPU beamformer[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2012, 59(7):1402-1412. [60] SUTCLIFFE M, WESTON M, DUTTON B, et al. Real-time full matrix capture for ultrasonic non-destructive testing with acceleration of post-processing through graphic hardware[J]. NDT&E International, 2012, 51:16-23. [61] 周正干,高翌飞,吕炎,等. 碳化硅颗粒增强铝基复合材料弹性常数测量[J]. 北京航空航天大学学报, 2009, 35(2):162-165. ZHOU Zhenggan, GAO Yifei, LÜ Yan. Elastic constant matrix measurement of SiCp reinforced aluminum metal matrix composites[J]. Journal of Beijing University of Aeronautics and astronautics, 2009, 35(2):162-165. [62] 周正干,高翌飞,何方成. 基于TIRP法的铝基复合材料均匀性检测[J]. 北京航空航天大学学报,2009, 35(8):1031-1034. ZHOU Zhenggan, GAO Yifei, HE Fangcheng. Homogeneity testing of aluminum metal matrix composites by TIRP method[J]. Journal of Beijing University of Aeronautics and astronautics, 2009, 35(8):1031-1034. [63] ZHANG J, HUNTER A, DRINKWATER B W, et al. Monte Carlo inversion of ultrasonic array data to map anisotropic weld properties[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2012, 59(11):2487-2497. [64] FAN Z, MARK A F, LOWE M J S, et al. Nonintrusive estimation of anisotropic stiffness maps of heterogeneous steel welds for the improvement of ultrasonic array inspection[J]. IEEE Transaction on Ultrasonics, and Frequency Control, Ferroelectrics, and Frequency Control, 2015, 62(8):1530-1543. [65] NJIKI M, ELOUARDI A, BOUAZIZ S, et al. A real-time implementation of the total focusing method for rapid and precise diagnostic in nondestructive evaluation[C]//IEEE 24th International Conference on Application-Specific Systems, Architectures and Processors (ASAP), 2013: 245-248. [66] POTTER J N, CROXFORD A J, WILCOX P D. Nonlinear ultrasonic phased array imaging[J]. Physical Review Letters, 2014, 113(14):144301-1-144301-5. |