等温容器内多孔介质分布对强化导热以及等温性能的影响*

杨丽红1, 沈航明2, 叶骞2, 刘成良2   

  1. 1. 上海理工大学机械工程学院 上海 200093;
    2. 上海交通大学机械与动力工程学院 上海 200240
  • 出版日期:2017-03-05 发布日期:2017-03-05
  • 作者简介:

    杨丽红(通信作者),女,1973年出生,博士,副教授。主要研究方向为传热传质结构优化、机械装备设计。

    E-mail:lhyang@usst.edu.cn

  • 基金资助:
    * 国家自然科学基金(51245009)和上海市自然科学基金(12ZR1420600)资助项目; 20160328收到初稿,20160927收到修改稿;

Influence of the Distribution of Porous Media on the Heat Conduction Enhancement and Isothermal Performance for Isothermal Chamber

YANG Lihong1, SHEN Hangming2, YE Qian2, LIU Chengliang2   

  1. 1. School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai 200093;
    2. School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240
  • Online:2017-03-05 Published:2017-03-05

摘要:

为了提高等温容器的等温性能,基于拓扑方法将内部细铜丝的分布对强化容器壁向中心导热的影响进行研究。建立导热模型,计算在均匀填充下横截面上的温度场以及容器中心温度。在容器壁温度、中心初始温度和细铜丝平均孔隙率一定的情况下,导热时间15 s,以中心温度最高为优化目标,分别采用线性变密度填充法和自适应成长法优化铜丝分布。两种优化结果的中心温度与均匀填充相比分别提高了0.6 ℃和2.62 ℃,并且得到了相应的铜丝分布曲线。将等温容器内部的铜丝根据优化结果进行分层填充后进行试验验证,先用导热试验说明改变细铜丝分布可以强化容器壁向中心的导热,接着用等温容器放气试验例证了该填充方案能够有效提高等温容器的等温性能。

关键词: 等温性能, 多孔介质, 强化导热, 等温容器

Abstract:

In order to improve the isothermal performance of isothermal chamber, the influence of the distribution of thin copper wire on the heat conduction enhancement from the wall to internal based on topological methods is studied. The heat conduction model is established, and the temperature fields and the center temperature are calculated under the condition that the copper wire is stuffed uniformly. Under the circumstance that the temperature of the container wall, the initial temperature in the center and the average stuffed density of thin copper wire are certain, taking the maximum of the center temperature as the optimization objective after 15 s heat conduction, the linear variable density filling method and the adaptive growth method are used respectively to optimize the distribution of copper wire. Compared with the uniformly filled, the results of the center temperature are increased 0.6 ℃ and 2.62 ℃ respectively, moreover the corresponding copper wire porosity distribution curves are obtained. The copper wire in the isothermal chamber is layered filled based on the optimized results and the verification experiments are carried out. From the experiment results, it is verified that changing the distribution of copper wire could enhance the heat conduction from the wall to internal and the filling scheme could improve the isothermal performance of isothermal isothermal.

Key words: heat transfer enhancement, isothermal performance, porous media, isothermal chamber