• CN:11-2187/TH
  • ISSN:0577-6686

机械工程学报 ›› 2015, Vol. 51 ›› Issue (4): 161-166.doi: 10.3901/JME.2015.04.161

• 可再生能源与工程热物理 • 上一篇    下一篇

扫码分享

周向重叠三分螺旋折流板换热器油-水传热性能试验研究

王伟晗1 程道来1 陈亚平2 董 聪3   

  1. 1. 上海应用技术学院城市建设与安全工程学院 上海 201418
    2. 东南大学能源与环境学院 南京 210096
    3. 浙江科技学院机械与汽车工程学院 杭州 310023
  • 出版日期:2015-02-20 发布日期:2015-02-20
  • 基金资助:
    国家自然科学基金资助项目(51276035)、上海市高校优秀青年教师培养资助计划项目(405ZK11YQ15)和上海市科委财政绿色能源与动力工程资助项目(4521ZK120064004)。

Experimental Study on Oil to Water Heat Transfer Performance of Circumferential Overlap Trisection Helical Baffle Heat Exchangers

WANG Weihan1 CHENG Daolai1 CHEN Yaping2 DONG Cong3   

  1. 1. College of Urban Construction and Safety Engineering, Shanghai Institute of Technology, Shanghai 201418
    2. School of Energy and Environment, Southeast University, Nanjing 210096
    3. School of Mechanical and Automotive Engineering, Zhejiang University of Science and Technology, Hangzhou 310023
  • Online:2015-02-20 Published:2015-02-20

摘要: 对倾斜角为12°、16°、20°、24°和28°的周向重叠三分螺旋折流板换热器和弓形折流板换热器的传热和压降性能进行试验研究。换热器采用公共壳体和可更换管芯结构,热流体与冷流体分别为70 ℃左右的导热油和11 ℃左右的冷却水。试验结果表明,在试验范围内周向重叠三分螺旋折流板换热器总体传热系数、壳侧传热系数、壳侧压降和综合性能综合指标ho/Δpo和ho/Δpo1/3都随着倾斜角增大而减小;倾斜角12°方案的性能指标最佳,其壳侧传热系数ho、综合性能指标ho/Δpo和ho/Δpo1/3与弓形折流板换热器的数值之比的平均值分别为1.253、1.391和1.285。

关键词: 螺旋折流板换热器, 倾斜角, 三分螺旋折流板, 性能试验, 周向重叠

Abstract: Experimental study on heat transfer performance of circumferential overlap trisection helical baffle heat exchangers of tilt angles 12°, 16°, 20°, 24°and 28° compared with a segmental baffle heat exchanger are conducted. The testing heat exchangers are constructed of a common cylinder case and replaceable tube bundle cores. The hot fluid is heat transfer oil with about 70 ℃ in the shell side and the cold fluid is cooling water with about 11 ℃ in the tube side. The results show that within the testing range, the overall heat transfer coefficient, the shell side heat transfer coefficient, pressure drop as well as comprehensive indexes ho/Δpo and ho/Δpo1/3 decrease with the increase of the tilt angle of the baffles, and the optimum scheme is the one with baffle tilt angle of 12°, and the ratios of the mean values of the shell side heat transfer coefficient ho, comprehensive index ho/Δpo and ho/Δpo1/3 of the helical scheme with baffle tilt angle of 12° over those of the segmental baffle scheme are 1.253, 1.391 and 1.285, respectively.

Key words: circumferential overlap, helical baffle heat exchanger, performance test, tilt angle, trisection helical baffle

中图分类号: