• CN: 11-2187/TH
  • ISSN: 0577-6686

Journal of Mechanical Engineering ›› 2026, Vol. 62 ›› Issue (17): 387-398.doi: 10.3901/JME.260917

Previous Articles    

Study on Line-focused Infrared Heating Technology in Automatic Fiber Placement Processing of Thermoplastic Composites

LIANG Jianguo1,2,3, LI Hui1,2, LIU Fengwei1,2, ZHANG Shuo1,2, LIU Jianglin1,2, WU Ting2   

  1. 1. College of Mechanical Engineering, Taiyuan University of Technology, Taiyuan 030024;
    2. Engineering Research Center of Advanced Metal Composites Forming Technology and Equipment of Ministry of Education, Taiyuan University of Technology, Taiyuan 030024;
    3. Xinjiang Intelligent Equipment Research Institute, Aksu 843000
  • Received:2025-09-10 Revised:2026-03-01 Published:2026-11-20

Abstract: A high-energy-density, rapid-response line-focused infrared heating technology is developed to overcome the limitations of conventional infrared heaters, which exhibit low energy density and are insufficient for the specific requirements of automated thermoplastic composite layup. The effects of process parameters on the temperature field during the automated layup of thermoplastic composites are systematically investigated. The thermal and radioactive transfer theories underlying line-focused infrared heating are analyzed, and a matching relationship among heating power, layup speed, and temperature is established to enable precise temperature control. A three-dimensional finite element model based on heat transfer principles is constructed to predict the evolution of the temperature distribution during the process. An in-situ temperature measurement platform is built on a custom-designed automated layup device employing line-focused infrared heating to experimentally verify the feasibility of the heating method and the accuracy of the finite element model. The results demonstrate that under the process parameters of a heating power of 770 W, a mold temperature of 25℃, and a placement speed of 30 mm/s, high-quality placement of CF/PPS prepreg can be achieved, confirming the feasibility of the proposed new equipment. Furthermore, the simulation results show good consistency with the experimental data, with a maximum temperature peak error of no more than 6% across layers, providing a reliable basis for the selection and optimization of process parameters in future automatic placement of thermoplastic composites.

Key words: thermoplastic composites, automated fiber placement, in-situ consolidation, infrared heating, temperature field

CLC Number: