Multi-source Feature Fusion and Tool Fault Diagnosis under Variable Spindle Speeds Based on Improved MFCC-CWT and Cycle GAN

ZHANG Yuyan, SHEN Guanghui, LI Hao, DU Wenliao, WANG Haoqi, LIU Yueyang   

  1. Zhengzhou University of Light Industry, Henan Provincial Key Laboratory of Intelligent Manufacturing of High-End Equipment, Zhengzhou 450002
  • Received:2025-11-03 Revised:2026-06-03 Published:2026-11-20

Abstract: To address the significant degradation of milling cutter fault diagnosis performance under variable spindle speed conditions,a multi-source feature fusion and fault diagnosis method for milling cutters based on improved MFCC-CWT and cycle-consistent generative adversarial network (Cycle GAN) is proposed. The method includes three aspects of improvement: dynamic-static mel frequency cepstral coefficients (MFCC) and enhanced continuous wavelet transform (CWT) feature maps are constructed to realize the joint representation of key information from acoustic and vibration signals; multimodal features are adaptively fused in a residual network embedded with a convolutional attention module to improve the discriminative ability for fault modes; conditional constraints are introduced into Cycle GAN to align feature distributions under different spindle speeds. Based on a self-built three-axis machine tool platform,a total of 9 000 groups of multi-source data were collected under three spindle speeds of 12 000 r/min,15 000 r/min,and 18 000 r/min,as well as five milling cutter states,for validation. The proposed method achieves a diagnosis accuracy of 99.40% at 12 000 r/min. When transferred to 15 000 r/min and 18 000 r/min,the accuracy of the method is improved from 69.03% and 44.47% to 95.97% and 93.63%,respectively,and an accuracy of 95.03% is still maintained under strong noise of 10 dB.

Key words: tool fault diagnosis, multi-source signal fusion, dynamic-static MFCC, enhanced CWT

CLC Number: