• CN: 11-2187/TH
  • ISSN: 0577-6686

Journal of Mechanical Engineering ›› 2026, Vol. 62 ›› Issue (16): 445-455.doi: 10.3901/JME.260734

Previous Articles    

Research on Dynamic Response of Permanent Magnet Direct-drive Locomotive Motor under Short-circuit Fault Conditions

ZHANG Yizhe1, CHU Gaofeng1, ZHANG Zhichao1, GAO Xiang1, SONG Andong2, CHEN Jiyong2   

  1. 1. Locomotive & Car Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081;
    2. Shanxi Key Laboratory of Rail Transit Locomotive System Integration, CRRC Datong Co., Ltd., Datong 037038
  • Received:2025-09-17 Revised:2026-03-09 Published:2026-10-14

Abstract: With the widespread application of permanent magnet synchronous motors(PMSM) in the field of rail transportation, the necessity of researching operational safety under fault conditions has become increasingly prominent. Although inter-phase short-circuit is not the most common fault type in PMSMs, its occurrence can seriously impact the operational safety of rail vehicles. To ensure the safe operation of permanent magnet direct-drive passenger locomotives during inter-phase short-circuit conditions and to explore the dynamic response of key structures under such fault scenarios, this test employs a vehicle rolling test bench and simulated normal operation as well as two-phase and three-phase short-circuit conditions using isolation contactors. The vibration and load time histories of key structures, including the locomotive motor, axle box, frame, and car body, are simultaneously recorded, while voltages and currents on both the motor side and converter output side are monitored. The study reveals that the vibration and load amplitudes on the short-circuit side generally reached more than five times those under normal conditions. The instantaneous response during a three-phase short-circuit is greater than that of a two-phase short-circuit, but its duration typically does not exceed 0.5 s. Although the frequency response characteristics of two-phase and three-phase short-circuit conditions differed significantly, both exhibited a high correlation with speed levels. This study systematically presents the amplitude-frequency characteristics of vibration and load in permanent magnet locomotive structures under motor inter-phase short-circuit conditions and investigates structural safety. The study provides data support for the safe application of PMSMs in the locomotive field, demonstrating significant engineering value.

Key words: PMSM, passenger locomotive, inter-phase short-circuit, structural vibration, load, amplitude-frequency characteristic