›› 2011, Vol. 47 ›› Issue (12): 106-112.
• Article • Previous Articles Next Articles
LIU Dongxiao;LI Yunze;LI Mingmin;LI Miao;LI Yunhua
Published:
Abstract: The implementation of energy-saving and fast dynamic thermal management (DTM) for electronic devices requires a low-interposition heat flux sensor (LI-HFS) with low thermal resistance and fast response ability. This paper illustrates the detailed operation principle of a new LI-HFS. Aiming at the response characteristics testing requirement of the LI-HFS, a testing system is built on the basis of static heat flow principle, and as a platform for LI-HFS sample test, the testing system is utilized to carry out testing research on steady state characteristics, such as input-output characteristic and temperature difference hysteresis characteristic, as well as dynamic characteristics under heat source step-power. Finally, taking HFS-4 heat flux sensor as reference standard, dynamic contrast test and error analysis on LI-HFS is performed. The results show that the LI-HFS, with good linearity, small hysteresis error and good dynamic measurement performance, is suitable for the interposition measurement of thermal conduction heat flow in DTM system for electronic devices.
Key words: Dynamic thermal management, Heat flux sensor, Response characteristics, Thermal conduction
CLC Number:
TP212
LIU Dongxiao;LI Yunze;LI Mingmin;LI Miao;LI Yunhua. Experiment Research on Responsive Characteristic of Low-interposition Heat Flux Sensor for Dynamic Thermal Management[J]. , 2011, 47(12): 106-112.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://www.cjmenet.com.cn/EN/
http://www.cjmenet.com.cn/EN/Y2011/V47/I12/106