• CN: 11-2187/TH
  • ISSN: 0577-6686

›› 2007, Vol. 43 ›› Issue (9): 61-64.

• Article • Previous Articles     Next Articles

EFFECT OF VISCOUS HEATING OF THE FLUID DAMPER ON THE WHOLE-SPACECRAFT VIBRATION ISOLATION

HE Ling;YANG Qingjun;ZHENG Gangtie   

  1. School of Astronautics, Harbin Institute of Technology School of Aerospace, Tsinghua University
  • Published:2007-09-15

Abstract: During a launch mission, the fluid damper has different damping coefficient and resonance frequency for the fluid viscosity is a function of the fluid temperature. A thermo-dynamic model is established by considering the application of the fluid damper in the whole-spacecraft vibration isolation. And the frequency domain performances of the whole-spacecraft vibration isolation systems at some time in-tervals are numerically studied with different viscos-ity-temperature coefficients and different parameters. The theoretical analysis and experimental results show that with the past of the time, the temperature of the damper increased, and thus resulted in a shift of the resonance frequency and the changes of the resonance amplitude.

Key words: Fluid damper, Temperature-dependent viscosity, Vibration isolation

CLC Number: