• CN: 11-2187/TH
  • ISSN: 0577-6686

›› 2003, Vol. 39 ›› Issue (9): 49-51.

• Article • Previous Articles     Next Articles

NUMERICAL STUDY FOR BEHAVIOR OF TIP CLEARANCE FLOW IN AXIAL-FLOW PUMP

Yang Changming;Chen Cichang;Wang Jinnuo;Song Wenwu;Xia Pengfei   

  1. Southwest Jiaotong University Sichuan University of Science and Technology
  • Published:2003-09-15

Abstract: Three-dimensional tip clearance flow in axial-flow pump is simulated based on N-S equations, standard k –e turbulence model, and SIMPLEC method, with various tip clearances of blade and work conditions. The influence of clearance flow on flow fields and performance of the rotor is investigated emphatically. The numerical result shows increasing the tip clearance will reduce hydrostatic head, especially at small flow rate.

Key words: Axial-flow pump, Clearance flow, Numerical simulation