Establishment and Verification of Finger Joint Kinematic Model Based on the Combination of Medicine and Engineering
YU Jinxu1,2, YAN Jianhua1,2, XIAO Junming3, LI Yongquan1,4, XIE Ping3, ZHANG Lijie1,2
1. Key Laboratory of Advanced Forging & Stamping Technology and Science (Yanshan University), Ministry of Education of China, Qinhuangdao 066004; 2. Hebei Provincial Key Laboratory of Heavy Machinery Fluid Power Transmission and Control, Yanshan University, Qinhuangdao 066004; 3. Key Laboratory of Intelligent Rehabilitation and Neuromodulation of Hebei Province, Institute of Electric Engineering, Yanshan University, Qinhuangdao 066004; 4. Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, Qinhuangdao 066004
YU Jinxu, YAN Jianhua, XIAO Junming, LI Yongquan, XIE Ping, ZHANG Lijie. Establishment and Verification of Finger Joint Kinematic Model Based on the Combination of Medicine and Engineering[J]. Journal of Mechanical Engineering, 2024, 60(15): 149-159.
[1] LIU C,LU J,YANG H,et al.Current state of robotics in hand rehabilitation after stroke:A systematic review[J].Applied Sciences,2022,12(9):4540. [2] LI Y,GAO X,LIAO B,et al.Research progress of exoskeleton for hand rehabilitation following stroke[J].Journal of Physics:Conference Series,2021,1820(1):012076. [3] 张立杰,于金须,闫建华,等.基于人机共融的外骨骼机构构型综合及优选方法[J].机械工程学报,2022,58(11):37-45.ZHANG Lijie,YU Jinxu,YAN Jianhua,et al.Synthesis and optimization method of exoskeleton mechanism based on human-machine fusion[J].Journal of Mechanical Engineering,2022,58(11):37-45 [4] 李剑锋,张兆晶,张雷雨,等.手部外骨骼运动相容性设计综述[J].上海交通大学学报,2018,52(6):729-742.LI Jianfeng,ZHANG Zhaojing,ZHANG Leiyu,et al.Review of the kinematic compatibility design of hand exoskeletons[J].Journal of Shanghai Jiaotong University,2018,52(6):729-742. [5] THOMPSON D E,BUFORD W L,MYERS L M,et al.A hand biomechanics workstation[J].ACM SIGGRAPH Computer Graphics,1988,22(4):335-343. [6] JOHANSON M E,SKINNER S R,LAMOREUX L W,et al.Phasic relationships of the extrinsic muscles of the normal hand[J].The Journal of Hand Surgery,1990,15(4):587-594. [7] RASH G S,BELLIAPPA P P,WACHOWIAK M P,et al.A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension[J].Journal of Biomechanics,1999,32(12):1337-1341. [8] COUPIER J,HAMOUDI S,TELESE-IZZI S,et al.A novel method for in-vivo evaluation of finger kinematics including definition of healthy motion patterns[J].Clinical Biomechanics,2016,31:47-58. [9] 康永强.2-5掌指关节屈伸活动中有效关节接触面积的三维可视化研究[D].苏州:苏州大学,2017.KANG Yongqiang.The 3D visualization study evaluating contact areas of the 2-5 metacarpophalangeal joint during flexion[D].Soochow:Soochow University,2017. [10] YANG J,XIE H,SHI J.A novel motion-coupling design for a jointless tendon-driven finger exoskeleton for rehabilitation[J].Mechanism and Machine Theory,2016,99:83-102. [11] LIANG R,XU G,TENG Z,et al.A general arthropod joint model and its applications in modeling human robotic joints[J].IEEE Access,2021,9:7814-7822. [12] PARK C B,PARK H S.Portable 3D-printed hand orthosis with spatial stiffness distribution personalized for assisting grasping in daily living[J].Frontiers in Bioengineering and Biotechnology,2023,11:895745. [13] PEPERONI E,CAPITANI S L,FIUMALBI T,et al.Self-aligning finger exoskeleton for the mobilization of the metacarpophalangeal joint[J].IEEE Transactions on Neural Systems and Rehabilitation Engineering,2023,31:884-894. [14] HAARMAN C J W,HEKMAN E E G,RIETMAN J S,et al.Mechanical design and feasibility of a finger exoskeleton to support finger extension of severely affected stroke patients[J].IEEE Transactions on Neural Systems and Rehabilitation Engineering,2023,31:1268-1276. [15] BARTALUCCI L,SECCIANI N,BROGI C,et al.An original mechatronic design of a kinaesthetic hand exoskeleton for virtual reality-based applications[J].Mechatronics,2023,90:102947. [16] ZHANG H.Design,modeling,and characteristic analysis of an index finger exoskeleton for rehabilitation[J].Journal of Physics:Conference Series,2022,2405(1):012012. [17] 张雷雨,李剑锋,刘钧辉,等.上肢康复外骨骼的设计与人机相容性分析[J].机械工程学报,2018,54(5):19-28.ZHANG Leiyu,LI Jianfeng,LIU Junhui,et al.Design and human-machine compatibility analysis of co-exos for upper-limb rehabilitation[J].Journal of Mechanical Engineering,2018,54(5):19-28. [18] MÜLLER-GERBL M,PUTZ R,HODAPP N,et al.Die darstellung der subchondralen dichtemuster mittels der ct-osteoabsorptiometrie (CT-OAM) zur beurteilung der individuellen gelenkbeanspruchung am lebenden[J].Zeitschrift für Orthopädie und ihre Grenzgebiete,2008,128(2):128-133. [19] VALENTIN J.Managing patient dose in multi-detector computed tomography (MDCT)[M].New York:Elsevier,2007. [20] SALTYBAEVA N,JAFARI M E,HUPFER M,et al.Estimates of effective dose for ct scans of the lower extremities[J].Radiology,2014,273(1):153-159. [21] HUDA W,OGDEN K M,KHORASANI M R.Converting dose-length product to effective dose at CT[J].Radiology,2008,248(3):995-1003. [22] 李亮,魏立友,王国强,等.小夹板与高分子石膏固定治疗桡骨远端骨折的疗效比较[J].中国骨与关节损伤杂志,2022,37(1):88-90. LI Liang,WEI Liyou,WANG Guoqiang,et al.Comparison of the efficacy of small splint and polymer plaster immobilization in the treatment of distal radius fracture[J].Chinese Journal of Bone and Joint Injury,2022,37(1):88-90. [23] 魏明杰.应用Mimics软件构建钩骨3D可视化解剖学研究[D].昆明:昆明医科大学,2021.WEI Mingjie.Application of MIMICS software to construct 3d visualization anatomy of hook bone[D].Kunming:Kunming Medical University,2021. [24] 李江涛.Mimics软件三维重建结合快速成形技术在骨折治疗中的探索[D].石家庄:河北医科大学,2014. LI Jiangtao.Exploration of MIMICS software 3D reconstruction combined with rapid prototyping in fracture treatment[D].Shijiazhuang:Hebei Medical University,2014. [25] SOMAN S,ANBURAJAN M.Finite element analysis of fractured finger with implant fixation using MIMICS[C]//20113rd International Conference on Electronics Computer Technology.Kanyakumari,India:IEEE,2011:380-385. [26] ZURL B,TIEFLING R,WINKLER P,et al.Hounsfield units variations:Impact on CT-density based conversion tables and their effects on dose distribution[J].Strahlentherapie und Onkologie,2014,190(1):88-93. [27] HESS F,FÜRNSTAHL P,GALLO L M,et al.3D analysis of the proximal interphalangeal joint kinematics during flexion[J].Computational and Mathematical Methods in Medicine,2013,2013:e138063. [28] VAN SINT JAN S,GIURINTANO D J,THOMPSON D E,et al.Joint kinematics simulation from medical imaging data[J].IEEE Transactions on Biomedical Engineering,1997,44(12):1175-1184. [29] YANG X,LIM Z,JUNG H,et al.Estimation of finite finger joint centers of rotation using 3D hand skeleton motions reconstructed from CT scans[J].Applied Sciences,2020,10(24):9129. [30] FIGUEROA R,ARMSTRONG T J,WOOLLEY C,et al.Determining instantaneous centers of rotation for finger joints through different postures using the iterative closest point algorithm (ICP)[J].Proceedings of the Human Factors and Ergonomics Society Annual Meeting,2016,60(1):1470-1474. [31] 沈乃勋,吕恬生,朱香亭,等.用解析法求取膝关节运动时的瞬心轨迹[J].中国生物医学工程学报,1986(1):61-66.SHEN Naixun,LÜ Tiansheng,ZHU Xiangting,et al.An analytical method to find the instantaneous center trajectory of the knee joint during motion[J].Chinese Journal of Biomedical Engineering,1986(1):61-66.