• CN: 11-2187/TH
  • ISSN: 0577-6686

Journal of Mechanical Engineering ›› 2015, Vol. 51 ›› Issue (10): 1-7.doi: 10.3901/JME.2015.10.001

    Next Articles

Research on Baseline-free Damage Imaging Method Employing Omni-directional S0 Mode Magnetostrictive Transducers

ZHOU Zhenggan1, PENG Di1, LI Yang1 , HU Hongwei1, 2   

  1. 1. School of Mechanical Engineering and Automation, Beihang University, Beijing 100191;
    2. School of Automotive and Mechanical Engineering, Changsha University of Science and Technology, Changsha 410114
  • Online:2015-05-15 Published:2015-05-15

Abstract: Total focusing method is an imaging approach using full matrix data which has become a research hotspot due to its advantages such as high accuracy, flexibility and so on. To solve the calibration problem in inspection with wedge coupled, full matrix data and its capture are described, a dual-medium energy attenuation model is established, three parts of calibration coefficient are given by analytical expressions which are directivity, transmission and diffusion attenuation, and a calibration based total focusing method is designed. Three images of the phased array test block type-B are formed using total focusing method. Experimental results show that it is good for the remote reflector with the calibration of root-square-distance, using the attenuation calibration model the attenuation caused by long path length and large deflection angle is better corrected and the energy of the image is more uniform. This calibration based total focusing method has the ability to detect the defects at large deflection angle. The research result shows that missing rate and sizing error can be reduced by calibration based total focusing method effectively.

Key words: calibration, full matrix data, total focusing method, ultrasonic phased array, wedge coupled

CLC Number: